在生产者/消费者模型中,消费者是连接发起人
(它会打开连接)。当几个消费者试图打开
连接到同一标签时,将打开连接以在
具有小API的使用者的速率(参见实际数据包间隔
-8页)。
生产者和消费者必须为指定的产品正确配置
要共享的数据。要为多个消费者生产,生产商必须
为此,使用Logix5550的RSLogix5000软件进行了配置
控制器。对于PLC-5C,发送和接收预定消息
使用RSNetWorx for ControlNet中的地图编辑工具进行配置。
对于ControlLogix控制器,消费者中的消费标签必须是
与生产商中生产的标签完全相同。在
以下示例中,consumer\u 2没有正确的标记。



In the producer/consumer model, the consumer is the connection originator (it opens the connection). When several consumers are trying to open the connection to the same tag, the connection will be opened to transfer data at the rate of the consumer with the smallest API (see Actual Packet Interval on page 1-8). The producer and consumer must be configured correctly for the specified data to be shared. To produce for several consumers, the producer must be configured for this using the RSLogix5000 software for the Logix5550 controller. For the PLC-5C send and receive scheduled messages are configured using the Map Editing Tool in RSNetWorx for ControlNet. For ControlLogix controllers, a consumed tag in the consumer must be specified exactly the same as a produced tag in the producer. In the following example, consumer_2 does not have the correct tags.